Q10 Wired Underfloor Heating Control

Q10 WIRED HEATING CONTROL

Wired underfloor heating control

Independent room-by-room control, stable wired communication and precise operation for heating systems designed correctly from the installation stage.

Quicksmart Q10 is ideal for new builds and complete renovations where electrical wiring can be planned in advance. Each thermostat controls an independent heating zone while the controller manages thermal actuators, circulation pump and boiler demand.

Reliable wired communicationIndividual room-by-room controlBoiler and circulation pump controlSmart thermostat options
View Q10 Wired systems
Complete Quicksmart Q10 wired underfloor heating control kit
WIRED MULTI-ZONE CONTROL

Precise control and long-term reliability

Quicksmart wired underfloor heating control systems combine room thermostats, a manifold controller and NC thermal actuators. Wired communication provides a stable connection and enables independent temperature control in every room.

Each wired thermostat sends heating demand directly to the Q10 controller. The controller opens the required manifold circuits and coordinates the circulation pump and boiler. The system can also be integrated with heat pumps depending on the electrical control interface of the heat source.

HOW IT WORKS

Components of the Q10 Wired system

Every component has a specific role in a complete multi-zone underfloor heating control system.

Quicksmart Q10 wired underfloor heating controller
Q10 Controller

The central unit for multi-zone heating control

The Q10 controller manages thermostats, thermal actuators, circulation pump and boiler demand for every heating zone.

QUICKSMART EUROPE CONFIGURATOR
Configure the right heating control system for your project

Choose a wired or wireless system, number of heating zones, thermostats and required components. The configurator calculates the system automatically.

Open configurator
Q10 OR Q20?

Wired reliability or wireless flexibility.

Q10 WIRED

Ideal for new builds and complete renovations

  • Wired connections between thermostats and controller
  • Surface-mounted or flush-mounted thermostats
  • Reliable independent zone control
  • Direct power supply depending on thermostat model
Q20 WIRELESS

Ideal for renovations and finished homes

  • No thermostat wiring between rooms and controller
  • Thermostats are easy to position or relocate
  • Individual zone control and app access
  • AA batteries or rechargeable battery, depending on model
View Q20 Wireless system →
MAKE AN INFORMED CHOICE

Benefits and important considerations

Why choose Q10 Wired

  • Stable wired communication without radio interference.
  • Independent temperature control by room or zone.
  • No thermostat battery replacement, depending on selected model.
  • Ideal for new builds and pre-wired projects.
  • Controller output for circulation pump and boiler.

What you should know before installation

  • Wiring is required between room thermostats and the manifold location.
  • Thermostat positions should be planned before wall finishes are completed.
  • Relocating thermostats later may require modifications to finished walls.
  • The number of actuators depends on manifold circuits, not simply the number of rooms.
FREQUENTLY ASKED QUESTIONS

Questions about wired underfloor heating control

How does a complete wired heating control system work?

Room thermostats measure temperature and send heating demand through wired connections to the Q10 controller. The controller operates the thermal actuators installed on the manifold and coordinates the circulation pump and boiler so that each zone receives heat only when required.

Can I control each room separately?

Yes. Each thermostat can control an independent temperature zone, and the controller opens only the manifold circuits assigned to that zone.

When is Q10 Wired recommended?

Q10 is particularly suitable for new builds and complete renovations where thermostat wiring can be installed before the walls and finishes are completed.

Is the system compatible with heat pumps?

Yes, the system can be integrated with heat-pump installations depending on the electrical control interface and wiring requirements of the heat source.

How many zones can a Q10 system control?

System configuration depends on the number of rooms and manifold circuits. Larger projects can use multiple controllers where required.

Can wired zone control reduce energy use?

Room-by-room control can reduce unnecessary heating and overheating. Actual energy savings depend on insulation, temperature settings, operating schedules, heat-source efficiency and overall system configuration.