Description
Q10 wired underfloor heating control for 4 zones – individual control with Q50 thermostats
This configuration is suitable for larger apartments, single-storey homes and installations with a main manifold. The 4 Q50 thermostats provide independent temperature control across the heating zones.
The system uses permanent wired communication between the thermostats and Q10 Controller. The controller coordinates the manifold actuators and can also manage circulation-pump and boiler demand.
With individual zoning, rooms can operate at different temperatures and the system activates only the circuits that actually require heat.
Quicksmart Q10 is designed for individual room-by-room underfloor heating control. The controller receives demand from the wired room thermostats, operates the manifold actuators and can also manage circulation-pump and boiler demand.

What is included in this Q10 Wired kit?
The quantities are detected automatically from the selected product configuration.
Important information about this Q10 Wired configuration
The Q10 system uses permanent wired connections between the room thermostats and the controller. The exact kit contents are shown above for the selected product.
Wired system
The room thermostats are connected by cable directly to the Q10 Controller. The controller receives heating demand from each zone and coordinates the corresponding manifold circuits.
Minimum 3 wires
The thermostat installation requires the appropriate wiring for permanent power supply and control communication. Plan the thermostat cabling before finishing walls or mounting boxes.
Smart Life directly from Q50
Remote app control is provided directly by the Q50 thermostats through Smart Life / Tuya. The wired Q10 system does not require a separate e-Hub gateway for this thermostat configuration.
Individual zone control
Each thermostat represents a temperature zone. One zone may control one or several underfloor-heating loops, depending on the manifold configuration.
Q10 kits can be ordered with or without actuators
If compatible actuators are already installed on the manifold, a configuration without actuators can be selected. When actuators are included, the quantity shown in this kit represents the controlled manifold circuits included in the selected product.
How Q10 Wired underfloor heating control works
Each thermostat monitors its room while the Q10 Controller coordinates the heating circuits and heat-source demand.
The thermostat measures room temperature
Each thermostat compares the measured temperature with the selected setpoint.
Demand reaches the Q10 Controller
The heating request is transmitted through the wired connection.
The required circuits open
The controller activates the actuator or actuators assigned to the requesting zone.
Pump and boiler demand can be activated
The Q10 Controller can request heat only when at least one zone needs heating.


Q10 Controller for wired underfloor heating control
The Q10 Controller is the central unit of the wired Quicksmart system. It receives demand from the room thermostats and manages the manifold actuators assigned to each heating zone.
One controller can manage up to 8 room thermostats and up to 32 actuators. A temperature zone may control one or several underfloor-heating circuits.
It can also control the circulation pump and provide boiler demand according to the active heating zones.
Q10 Controller technical data
Q50 Wired WiFi Thermostat with Touchscreen
Premium wired thermostat with colour touchscreen, glass front panel, Smart Life / Tuya and flush mounting.
This thermostat is designed for flush installation in a wall box, creating a clean and integrated finish.
The thermostat is permanently powered and communicates with the Q10 Controller through the wired installation. Smart Life / Tuya provides remote temperature control and scheduling.
Q50 thermostat technical data




NC thermal actuators for underfloor-heating manifolds
Quicksmart electrothermal actuators are installed on the manifold and allow the Q10 Controller to open or close the heating circuits assigned to each temperature zone.
This configuration contains 8 NC actuators. The actuator quantity represents the number of controlled manifold circuits, not necessarily the number of rooms.
Q10 kits can also be configured without actuators when compatible actuators are already installed on the manifold.
Quicksmart NC actuator technical data
See the Q50 thermostat in use
Product presentation and key functions of the selected wired thermostat.
Q50 wired thermostat
Premium wired thermostat with colour touchscreen, glass front panel, Smart Life / Tuya and flush mounting.
Q10 wired system connection examples
Connection examples for thermostats, manifold actuators, circulation pump and heat-source demand.
Thermostat and actuator connections
Wired room thermostats connect to the Q10 Controller. The controller centralises heating demand and operates the actuators assigned to each zone.


Room-by-room underfloor heating control
The complete architecture combines room thermostats, the Q10 Controller, manifold actuators, circulation-pump demand and the heat source.
Wireless / Wired Heating Control Installation Manuals
Choose the correct manual for your Quicksmart Q20 Wireless or Q10 Wired system and download the PDF installation and configuration guide.
Q20 Wireless Heating Control
Wireless Thermostats – Smart WiFi
Q10 Wired Heating Control
Wired Thermostats – Smart WiFi
Frequently asked questions
Answers about the configuration, installation and use of this kit.